Self-shielded flux cored wire is used for all-position welding,with little spatter,warming electric arc,easily moved slag.
GB E501T8-K6,AWS E71T8-K6,YC-E501T8-K6
Self-shielded flux cored wire
1.Decription:Self-shielded flux cored wire is used for important welding in the outside,just as pipe laying,petroleum platform on ocean,ships,bridges,metallurgy equipment,petroleum chemical combination,ect.
2.Application:It is suitable for semi-automatic welding where the impact tenacity is not applicable,It is used for the thin plate of welding with single pass welding,overlap welding,angle welding and butt welding,
3. Dry extension of electrode should be controled between 15mm and 25mm.
4.Mechanic property of deposit metal
ITEM
TENSILE STRENGTHMpa
ELOGATION%
IMPACT STRENGTHMpa
AWS E71T8-K6
580
13
29
5.Chemical composition of deposit metal
ITEM
C
Si
Mn
S
P
AWS E70T8-Ni1
0.08
0.30
1.26
0.002
0.015
6.Working parameters
WORKING
WELDINGWAYS
0.8mm
0.9mm
1.0mm
CURRENT(A)
Flat welding
horizontal fillet welding
40~110
40~130
50~180
VOLTAGE(V)
Flat welding
horizontal fillet welding
15~18
15~20
18~22
7.Packing:0.45kg/1kg/5kg spool sealed into box.