we are the professional in produce the pvc weldin cable for more than 10 yeas,the cross sections is 10-185mm2
Welding Cable
Conductors :
The conductors are drawn from bright electrolytic grade copper, and annealed-conductors are bunched together.
Thickness of Covering
Nominal Cross-Sectional Area of Conductor
Nominal Thickness of Covering (tc)
(1)
(2)
mm
2
mm
16
2.00
25
2.00
35
2.00
50
2.20
70
2.40
95
2.60
Current Rating of General Serivce Normal Duty Elastomeric Compund Covered Cable with Copper Conductor
Nominal Cross-Sectional Area of Conductor
Current Rating at a Maximum Duty Cycle of
100%
85%
60%
30%
20%
(1)
(3)
(4)
(5)
(6)
(7)
mm2
A
A
A
A
A
16
94
102
121
172
210
25
125
136
161
228
279
35
156
169
201
285
349
50
197
214
254
360
440
70
248
269
320
453
555
95
299
342
386
546
669
Current rating of HOFR
Normal
Duty Electomeric Compound Covered Cable with
Copper Conductor
Nominal Cross-Sectional Area of Conductor
Current Rating at a Maximum Duty Cycle of
100%
85%
60%
30%
(1)
(2)
(3)
(4)
(5)
mm2
A
A
A
A
16
135
146
174
246
25
177
192
228
343
35
221
240
285
403
50
279
303
360
509
70
352
382
454
643
95
424
460
547
774