Saturday, January 8, 2011

rubber or pvc insulated welding cable

rubber or pvc insulated welding cable
oxygen-free copper wire
good resistance to heat,aging,oil,corrosion,soft
IEC60245
rubber or pvc insulated welding cable
1,
Application
This rubber welding cable is suitable for the welding machine that voltage to the ground is not more than 200V and pulsating current value is 400V
2,
Model, Names and Work In the Temperature
Model
Name
Working temperature of core ≤
0
C
YH
Natural Rubber Sheath for Welding Cable
65
YHF
Neoprene Rubber Sheath Welding Cable
65
Synthetic Rubber Sheath Welding Cable

3.standard
1.Standardthe welding cable can be produced according to the standard GB5013.6-1997
and 245 IEC 81 for YH and 245 IEC 82 for YHF

4.Specifications, Size, Weight and Technical Data
Conductor Nominal Section (mm2)
Conductive Core
Thickness of Section Sheath (mm)
Average Outer Diameter (mm2)
20
0
C Conductor Resistance≤(Ω/km)
Reference Weight(kg/km)
Number/Diameter of Core(mm)
Min
Max
YH
YHF
10
322/0.20
1.8
7.5
9.7
1.91
146
153.51
16
513/0.20
2.0
9.2
11.5
1.16
218.9
230.44
25
798/0.20
2.0
10.5
13.0
0.758
316.6
331.15
35
1121/0.20
2.0
11.5
14.5
0.536
426
439.87
50
1596/0.20
2.2
13.5
17.0
0.379
592.47
610.55
70
2214/0.20
2.4
15.0
19.5
0.268
790
817.52
95
2997/0.20
2.6
17.0
22.0
0.198
1066.17
1102.97
120
1702/0.30
2.8
19.0
24.0
0.161
1348.25
1392.55
150
2135/0.30
3.0
21.0
27.0
0.129
1678.5
1698.72
185
1443/0.40
3.2
22.0
29.0
0.106
1983.8
2020.74

Note:
we
,Henan Amity Industry Co., Ltd,
with 16 years of manufacturing experience in cables and wires , enjoys a good reputation in providing clients quality products with the best services at home and abroad. Any item is of interest to you,please tell us the speicifications,we will provide you with competitive price and detailed information at the earliest time.